Heat detectors are cheap so use plenty of them.
Installing heat detector in attic.
Page 1 of 2 heat detectors in an attic.
Spot type heat detector spacing ratings are based on detector installation on a flat smooth ceiling that is 10 feet 3 m high.
The best place to install a heat detector is a location that needs to be monitored for fires.
Smoke alarms are not designed for garages and attics and are much more likely to fail than a heat detector.
With heat detectors this figure is 7 5m x 7 5m giving an area of coverage of 56m per device which is rounded down to 50m.
Pick installation locations 1.
Posted in home automation.
Pull the tape measure out as.
The area should be unique in that it is not suitable for a standard smoke detector.
Bs 5839 states that detectors should be sited no less than 0 5m from a wall.
The us fire administration fema recommends that you have a heat detector rather than a smoke alarm in your garage.
Hold the end of the tape measure at the highest point on a cathedral or gabled ceiling.
Heat detectors are usually installed in areas that often feature dust or smoke that may otherwise set off a standard smoke detector.
It gets very hot up there in the summer southern california so i thought it would be prudent to install a few high temperature heat sensors i bought 3 194 degree heat detectors.
It takes no electricity or batteries just wind it up and mount it.
Line type heat.
I was at a seminar on smoke detectors earlier this year and they had a wind up heat detector.
All i have a relatively large attic that covers about 1600 sq ft of my house.
Spot type detector spacing is.
Tack a string to the peak at the highest point so you know where the approximate center of the space is located.
By the irc international residential code smoke detectors are not required in the attic.
When i get home tonight i will look for the brochure and post it tomorrow.
Ceiling mounted heat detector shall be located not less than 4 inch from side wall sidewall mounted heat detector shall be located between 4 and 12 inches from the ceiling.
The listed spacing equates detector operation with the opening of a standard sprinkler head within 2 minutes 10 seconds located 10 feet 3 m from the same fire.
Attic venting is always a requirement to prevent condensation buildup irrespective of any energy concerns.
This will not guarantee that temperatures will stay below 135 degrees however so 200 degree detectors are a good idea.
Another location in a home where you should have a heat detector rather than a smoke alarm is the attic.